ABB 3ABD00047987-D — AC Drive (VFD) 480V

ABB 3ABD00047987-D ACS580-01-026A-4, 11 kW, 25 A VFD

MPN3ABD00047987-D
Active

ABB ACS580-01-026A-4+X1664, 3ABD00047987-D, 11 kW normal-use VFD, 25 A output, 380-480 V, IP21, IE2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3ABD00047987-D — Power & Output
ParameterValue
Output power, normal duty11 kW
Output current, normal duty25 A
Output power, heavy duty7.5 kW
Output current, heavy duty17.0 A
Output power, light overload11.0 kW
Output current, light overload23.8 A
Efficiency class (IE)IE2

Input / Supply

3ABD00047987-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00047987-D — Mechanical & Cooling
ParameterValue
Frame sizeR2
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted

Product details

The ABB 3ABD00047987-D is an ACS580-01 wall-mounted general-purpose drive for 3-phase induction motors. It delivers 11 kW (25 A) in normal use and 7.5 kW (17.0 A) in heavy-duty use, so the heavy-duty rating is the one to size against if the load profile includes frequent starts or peak torque demands. Input range is 380-480 V at 47.5-63 Hz, covering standard global line voltages. The IP21 enclosure and NEMA Type 1 rating suit clean indoor panel environments; wall-mounting keeps floor space clear.

The frame size is R2, which determines physical mounting footprint and gland plate layout for cable entry. The heavy-duty output current of 17.0 A is the figure to check against motor full-load amps if the application demands constant torque below base speed or intermittent overloads. Light-overload use (PlD 11.0 kW, IlD 23.8 A) provides an intermediate sizing point for variable-torque loads like fans and pumps where peak current is infrequent.

Frequently asked questions

What is the frame size of 3ABD00047987-D?

Frame size R2. This affects mounting dimensions and the available options slot layout.

What is the difference between the normal-use and heavy-duty ratings?

Normal use (Pn 11 kW, In 25 A) is for constant-torque loads at rated speed. Heavy-duty use (PhD 7.5 kW, IhD 17.0 A) applies when the drive must deliver higher starting torque or sustain overloads — size to the heavy-duty current if the motor may be pushed beyond its base speed or if the load profile includes frequent acceleration.

MPN
3ABD00047987-D