Drive selection memo — 3ABD00048143
LV AC machinery drive module, 4 kW normal-use output at 9.4 A, 380-480 V 3-phase input, Frame R1.
The drive carries three duty ratings, so you pick the one that matches your load profile. Normal use (Pn) is 4 kW at 9.4 A — that's the standard rating for a constant-torque fan or pump. Heavy-duty use (PhD) drops to 3 kW at 7.2 A, which covers high starting torque or shock loads. Light-overload use (PlD) stays at 4 kW but at 8.9 A, for variable-torque applications like centrifugal pumps.
Input and enclosure — what fits the panel
Input voltage range is 380-480 V, 3-phase, 47.5-63 Hz. IP20 enclosure and NEMA Open Type for indoor panel mounting.