Skip to main content
ABB 3ABD00048278-D — AC Drives (VFD)

ABB 3ABD00048278-D ACS580 drive, 0.75 kW, 2.6 A, IP21

MPN3ABD00048278-D
Active

ABB ACS580-01 general-purpose wall-mounted drive, 0.75 kW, 2.6 A, 380-500 V, IP21, NEMA 1, IE2, frame R1.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical

3ABD00048278-D — Electrical
ParameterValue
Input voltage380 ... 500 V
Frequency47.5 ... 63 Hz
Number of phases3-phase

Power & Current

3ABD00048278-D — Power & Current
ParameterValue
Output power, normal duty0.75 kW
Output power, heavy duty0.55 kW
Output power, light-overload duty0.75 kW
Output current, heavy duty1.8 A
Output current, normal duty2.6 A
Output current, light-overload duty2.5 A
Efficiency class (IE)IE2

Protection & Environmental

3ABD00048278-D — Protection & Environmental
ParameterValue
Degree of protection (IP)IP21
NEMA enclosure typeType1

Mechanical

3ABD00048278-D — Mechanical
ParameterValue
Frame sizeR1
Mounting typeWall-mounted

Product details

The ABB 3ABD00048278-D is a frame R1 ACS580-01 general-purpose wall-mounted drive rated for 0.75 kW normal-use output at 2.6 A on a 380–500 V three-phase supply. Heavy-duty use drops to 0.55 kW and 1.8 A, so if you're sizing for a constant-torque load like a conveyor or positive-displacement pump, the heavy-duty numbers are the ones that govern fit. Light-overload use (typically for fans or centrifugal pumps) lands at 0.75 kW / 2.5 A — close to normal duty but with a slightly lower current ceiling. The drive accepts line frequencies from 47.5 to 63 Hz, covering both 50 and 60 Hz grids without a configuration change.

IP21 and NEMA Type 1 enclosure means it's drip-proof and suitable for indoor panel or wall mounting where no hose-down or dust is present. Wall-mounting is the listed method — no cabinet floor kit needed for this frame size. The frame R1 footprint is compact enough for a small panel; keep the gland plate clear for incoming power and motor leads. No derating needed for ambient up to 40 °C, but if the panel runs hot, plan for some headroom on the output current.

Rated IE2 efficiency level, which meets the minimum for most general-purpose applications in regions where IE2 is still accepted (some markets now require IE3 for certain power ranges, so check local motor efficiency regulations). The WEEE category is small equipment (external dimension under 50 cm), which affects end-of-life disposal paperwork but not day-to-day operation.

Frequently asked questions

What is the frame size of this drive?

The frame size is R1, which is the smallest frame in the ACS580-01 family.

What is the difference between normal-use and heavy-duty ratings?

Normal-use rating is 0.75 kW / 2.6 A for light variable-torque loads like fans. Heavy-duty rating is 0.55 kW / 1.8 A for constant-torque loads like conveyors or positive-displacement pumps. Use the heavy-duty numbers for sizing when the load profile is unknown or demanding.

MPN
3ABD00048278-D