Skip to main content
ABB 3ABD00048312-D — Inverter / VFD

ABB 3ABD00048312-D ACS580-01-046A-4+P974, 22 kW 45 A, Frame

MPN3ABD00048312-D
Active

ABB ACS580-01 series, order code 3ABD00048312-D, general-purpose wall-mounted LV AC drive, 22 kW / 45 A normal duty, IP21, NEMA 1, frame size R3.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00048312-D specifications
ParameterValue
MountingWall-mounted
Enclosure type NEMAType1
Input voltage380 ... 500 V
Output current, normal use45 A
Output current, Heavy-Duty use37.7 A
Output current, Light-Overload use42.8 A
Output power, normal use22 kW
Output power, Heavy-Duty use18.5 kW
Output power, Light-Overload use22 kW
Frequency47.5 ... 63 Hz
Phases3-phase
IP ratingIP21
Frame sizeR3
Efficiency levelIE2

Product details

The 3ABD00048312-D: This drive carries three duty ratings. Normal use (Pn 22 kW, In 45 A) covers constant-torque loads like conveyors and fans at full speed. Heavy-duty use (PhD 18.5 kW, IhD 37.7 A) applies to higher-torque demands such as crushers or extruders where sustained overload matters. Light-overload use (PlD 22 kW, IlD 42.8 A) sits between the two, matching the normal power but at a slightly lower current — useful for variable-torque pumps or compressors where the load profile doesn't need the full 45 A headroom.

Wall-mounted in frame R3, with an IP21 / NEMA Type 1 enclosure — suitable for indoor, dry environments where dripping water or falling dirt isn't an issue. The NEMA Type 1 rating means it's protected against incidental contact but not hose-down or dust. Keep the top and side clearances per the installation manual for airflow; frame R3 drives pull enough heat that tight enclosures will derate the output. The wall-mount bracket pattern is standard for this frame size, so swapping in a spare means the same footprint and gland-plate arrangement.

Frequently asked questions

What is the frame size of this drive?

Frame size R3. This determines mounting hole pattern, gland-plate dimensions, and clearance requirements for airflow.

What are the key output ratings?

Normal duty: 22 kW at 45 A. Heavy duty: 18.5 kW at 37.7 A. Light overload: 22 kW at 42.8 A. Input is three-phase 380–500 V, 47.5–63 Hz.

What enclosure protection does it have?

IP21 and NEMA Type 1. Suitable for indoor use where no water spray or dust ingress is expected.

How do I source this drive?

It is an active catalog item, quoted to order against an RFQ. No stock or lead-time numbers are provided here.

MPN
3ABD00048312-D