Skip to main content
ABB 3ABD00048504-D — AC Drive (VFD) 480V

ABB 3ABD00048504-D ACS580 Drive, 5.5 kW, 12.6 A, IP20

MPN3ABD00048504-D
Active

ABB ACS580-01 general-purpose drive, 3ABD00048504-D, 5.5 kW normal-use, 12.6 A, 380-480 V, IP20, wall-mounted, frame size R1.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3ABD00048504-D — Power & Output
ParameterValue
Output power, normal duty5.5 kW
Output current, normal duty12.6 A
Output power, heavy duty4.0 kW
Output current, heavy duty9.4 A
Output power, light overload5.5 kW
Output current, light overload12.0 A
Efficiency class (IE)IE2

Input / Supply

3ABD00048504-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00048504-D — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeWall-mounted

Product details

The ABB 3ABD00048504-D is a general-purpose wall-mounted drive for 3-phase induction motors. It delivers 5.5 kW in normal use (12.6 A) and 4.0 kW in heavy-duty use (9.4 A) from a 380-480 VAC supply.

The drive is rated IE2 efficiency. Normal-use output is 5.5 kW / 12.6 A; heavy-duty drops to 4.0 kW / 9.4 A — so if your motor is oversized for the load, the heavy-duty rating is the one that keeps the drive out of thermal overload. Input accepts 380-480 VAC at 47.5-63 Hz, covering 50 and 60 Hz grids without adjustment. Enclosure is IP20 (open type), so it needs a clean, dry cabinet — no outdoor mounting without a secondary enclosure.

Wall-mounted, frame R1. The IP20 rating means it's for indoor cabinet mounting only. The 380-480 V three-phase input is standard for European and North American industrial supplies. Normal-use current of 12.6 A dictates the upstream breaker and cable sizing — 4 mm² copper is typical for runs under 50 m. Heavy-duty at 9.4 A gives headroom if the motor runs a hard cyclic load.

Frequently asked questions

What is the frame size?

Frame size is R1, which is the smallest frame in the ACS580-01 range.

What input voltage and frequency does it accept?

Input voltage is 380-480 VAC, 3-phase, at 47.5-63 Hz.

What are the normal-use and heavy-duty output ratings?

Normal-use output is 5.5 kW / 12.6 A; heavy-duty output is 4.0 kW / 9.4 A.

What is the enclosure type and protection rating?

Enclosure is NEMA Open Type, IP20. It requires installation inside a clean, dry cabinet.

MPN
3ABD00048504-D