Skip to main content
ABB 3ABD00048684-D — AC Drive (VFD) 480V

ABB 3ABD00048684-D ACS580-01-09A5-4+X1574 Drive, 4 kW, 9.4 A

MPN3ABD00048684-D
Active

ABB ACS580-01 general purpose LV AC drive, 3ABD00048684-D, Frame R1, 4 kW / 9.4 A normal use, 380-480 V 3-phase, IP21, IE2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00048684-D — Power & Output
ParameterValue
Output power, normal duty4 kW
Output current, normal duty9.4 A
Output power, heavy duty3.0 kW
Output current, heavy duty7.2 A
Output power, light overload4.0 kW
Output current, light overload8.9 A
Efficiency class (IE)IE2
3ABD00048684-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00048684-D — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted

Product details

Drive selection for the install window

The 3ABD00048684-D is an ABB ACS580-01 general-purpose wall-mounted drive rated 4 kW normal-use power at 9.4 A output current on a 380-480 V three-phase supply. Frame R1 keeps the panel footprint compact for a 4 kW machine; the IP21 enclosure suits clean indoor environments without additional cabinet protection. Efficiency class IE2 meets the baseline for most industrial applications where premium IE3 is not contractually required.

Three overload profiles are defined: normal use at 4 kW / 9.4 A, heavy-duty at 3.0 kW / 7.2 A, and light-overload at 4.0 kW / 8.9 A. The heavy-duty figure governs continuous operation on a constant-torque load like a conveyor or positive-displacement pump; the normal-use figure covers variable-torque loads (centrifugal fans, pumps) where the drive can run at the higher current without exceeding thermal limits. Light-overload matches the normal-use power but at a slightly lower current, which may apply when the motor is oversized relative to the load.

Frame R1 dimensions should be verified against the panel layout to confirm gland-plate clearance and cable bend radius for the incoming 3-phase supply.

Frequently asked questions

What is the difference between normal-use and heavy-duty ratings on this drive?

Normal-use rating is 4 kW / 9.4 A for variable-torque loads; heavy-duty rating is 3.0 kW / 7.2 A for constant-torque loads. The heavy-duty figure is the one to use when sizing for conveyors or positive-displacement pumps.

MPN