The 3ABD00048688-D: The normal-use (Pn) rating of 15 kW and 32 A is the continuous output for typical centrifugal pumps, fans, and light conveyors. The heavy-duty (PhD) rating drops to 11.0 kW at 24.6 A — that is the figure to use for constant-torque loads like screw feeders, extruders, or positive-displacement pumps where peak torque demand is higher. A light-overload rating (PlD) of 15.0 kW at 30.4 A sits between the two, covering applications with occasional overloads but not sustained heavy torque.
Wall-mounted in a NEMA Type 1 enclosure with IP21 protection — suitable for indoor, dry locations where dripping water or incidental contact is not a concern. Frame size R3; verify the mounting footprint against your backplate layout before committing the panel cutout.