Skip to main content
ABB 3ABD00048694-D — AC Drive (VFD) 480V

ABB 3ABD00048694-D ACS580-01-106A-4, 55 kW LV AC Drive, IP21

MPN3ABD00048694-D
Active

ABB ACS580-01-106A-4, 3ABD00048694-D, LV AC general-purpose wall-mounted drive, 380–480 V, 55 kW / 106 A normal use, IP21, NEMA Type 1, Frame R5.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Power & Output

3ABD00048694-D — Power & Output
ParameterValue
Output power, normal duty55 kW
Output current, normal duty106 A
Output power, heavy duty45 kW
Output current, heavy duty87 A
Output power, light overload55 kW
Output current, light overload100 A
Efficiency class (IE)IE2

Input / Supply

3ABD00048694-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz

Mechanical & Cooling

3ABD00048694-D — Mechanical & Cooling
ParameterValue
Frame sizeR5
NEMA enclosure typeType1
Degree of protection (IP)IP21
Mounting typeWall-mounted

Product details

Drive selection memo – 55 kW class, wall-mount

The ABB 3ABD00048694-D is a general-purpose LV AC wall-mounted drive rated for 55 kW normal use at 106 A, with a 380–480 V three-phase input. It carries an IE2 efficiency level and an IP21 / NEMA Type 1 enclosure.

Heavy-duty vs normal-use headroom

The drive carries two duty ratings: 55 kW / 106 A for normal use, and 45 kW / 87 A for heavy-duty use. If your load profile includes sustained overloads or high starting torque, size against the heavy-duty numbers — that 87 A continuous is the line for constant-torque applications like conveyors or extruders.

Installation notes

Wall-mounted only — no flange kit or floor-standing adapter in this order code. The IP21 / NEMA 1 enclosure suits clean, dry indoor environments.

Frequently asked questions

What is the frame size of this drive?

Frame size R5 — that determines the mounting footprint and the available options slot layout.

What are the normal-use and heavy-duty output ratings?

Normal use: 55 kW / 106 A. Heavy-duty use: 45 kW / 87 A. Light-overload use: 55 kW / 100 A.

What enclosure protection does this drive have?

IP21 with NEMA Type 1 enclosure — suitable for indoor, dry locations where dripping water and falling dirt are the main hazards.

MPN
3ABD00048694-D