Load ratings and duty selection
The 3ABD00048705-D: The drive carries three distinct output ratings. Normal use (Pn) delivers 2.2 kW at 5.6 A, suitable for constant-torque applications like conveyors or pumps. Heavy-duty use (PhD) is 1.5 kW at 4.0 A, intended for higher overload capability on loads such as crushers or extruders. Light-overload use (PlD) also lists 2.2 kW but at 5.3 A, reflecting a slightly lower current limit for less demanding cycles. The IE2 efficiency level applies across these ratings.