The ABB 3ABD00049839 is an ACQ531-01-363A-4+J400 drive rated for 200 kW output at normal use, with a continuous output current of 363 A. It runs on 380-480 V three-phase input, 47.5-63 Hz, and carries IE2 efficiency. Frame size R9, wall-mounted, IP20, open-type NEMA enclosure.
The light-overload rating is 345 A (IlD), also at 200 kW, which gives a bit of headroom for short-duration overloads without stepping up a frame. Input voltage covers 380-480 V, so it lands on standard 400 V or 480 V grids without a transformer. IP20 means it's for indoor panel mounting, not washdown areas. IE2 efficiency meets current minimum standards for most regions; if the site requires IE3 or IE4, this won't qualify.
Mounting and enclosure notes
Wall-mounted, frame size R9. Open-type NEMA means it's not a standalone enclosure — it goes inside a panel or cabinet that provides the environmental seal. The IP20 rating confirms that. No gland-plate dimensions or bolt pattern are listed here, but the R9 frame is a known ABB standard; the mounting hole layout and cable entry are consistent across the ACQ531 R9 builds.