ABB 3ABD00049850 — AC Drive (VFD) 480V

3ABD00049850 ABB ACQ531-01-033A-4+0J404 VFD, 15 kW, 32 A, Fr

MPN3ABD00049850
Active

ABB ACQ531-01-033A-4+0J404, Frame R3, 15 kW / 32 A, 380–480 V 3-phase, IP20, IE2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00049850 — Power & Output
ParameterValue
Output power, normal duty15 kW
Output current, normal duty32 A
Output power, light overload15 kW
Output current, light overload30.4 A
Efficiency class (IE)IE2
3ABD00049850 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00049850 — Mechanical & Cooling
ParameterValue
Frame sizeR3
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeWall-mounted

Product details

Drive fit and ratings

The ABB 3ABD00049850 is an ACQ531-01-033A-4+0J404 variable-frequency drive in Frame R3, rated 15 kW output at 32 A on a 380–480 V three-phase supply. That 32 A figure is the normal-use current; light-overload duty (PlD) holds at 15 kW but draws 30.4 A, so the drive handles the same power with slightly less headroom for sustained overloads. The IE2 efficiency class is the baseline for this generation — expect standard losses, not premium-motor matching.

Wall-mounted, IP20, NEMA Open Type. That means it lives inside a cabinet or controlled environment — no washdown, no dust. Frame R3 is a compact form factor; the wall-mount bracket is integral. Leave the standard top and bottom clearance for airflow; the IP20 rating doesn't tolerate condensation.

Line and frequency compatibility

Input frequency range is 47.5 to 63 Hz, so it covers both 50 Hz and 60 Hz grids without derating. The 380–480 V input window spans 400 V and 480 V nominal systems — common in European and North American industrial plants. No neutral required; it's a 3-phase-only unit.

Frequently asked questions

What is the frame size of 3ABD00049850?

Frame R3. That's the mechanical envelope for this drive — determines mounting footprint and panel cutout.

What is the output current rating?

32 A normal use (In) and 30.4 A light-overload use (IlD), both at 15 kW output power.

MPN
3ABD00049850