ABB 3ABD00049995-D — AC Drives (VFD)

3ABD00049995-D ABB ACS530-01-025A-4+P973 Drive, 11 kW, 25 A,

MPN3ABD00049995-D
Active

ABB ACS530-01-025A-4+P973, 11 kW, 25 A, 380-500 VAC, 3-phase, frame size B2, IE2, IP20, wall-mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical

3ABD00049995-D — Electrical
ParameterValue
Input voltage380 ... 500 V
Frequency47.5 ... 63 Hz
Number of phases3-phase

Power & Current

3ABD00049995-D — Power & Current
ParameterValue
Output power, normal duty11 kW
Output power, light-overload duty11 kW
Output current, normal duty25 A
Output current, light-overload duty23.8 A
Efficiency class (IE)IE2

Protection & Environmental

3ABD00049995-D — Protection & Environmental
ParameterValue
Degree of protection (IP)IP20
NEMA enclosure typeOpen Type

Mechanical

3ABD00049995-D — Mechanical
ParameterValue
Frame sizeB2
Mounting typeWall-mounted

Product details

The 3ABD00049995-D: The ABB ACS530-01-025A-4+P973 is a 3-phase variable frequency drive rated for 11 kW normal-use output power and 25 A output current, with a light-overload rating of 11 kW at 23.8 A. It accepts a 380-500 VAC input over a 47.5-63 Hz range, and is housed in frame size B2 with IP20 protection for wall-mounted installation. IE2 efficiency class is standard on this unit, matching the motor efficiency tier common in fixed-speed replacement and variable-torque applications. The frame B2 footprint keeps the drive compact for panel layouts where space is at a premium.

For BOM freeze or PCN-watch purposes, this drive is a stable line item — no imminent obsolescence risk.

The 25 A normal-use output current (23.8 A light-overload) sets the motor full-load ampacity it can drive continuously. For a 400 VAC supply, 11 kW aligns with a standard 4-pole induction motor frame. IP20 enclosure is suited for clean indoor panel environments — no washdown or dust protection. Wall-mounting with open-type NEMA rating means the drive expects to be inside a cabinet that provides the environmental seal. Frequency tolerance from 47.5 to 63 Hz covers both 50 Hz and 60 Hz mains, plus generator or weak-grid scenarios where frequency may drift. No derating is implied across that band, but verify with the thermal derating curve for sustained operation at the low end.

Frequently asked questions

What is the frame size of this drive?

Frame size is B2, which determines the physical mounting footprint and the available options slot configuration.

What is the output power and current rating?

Normal-use output is 11 kW at 25 A; light-overload rating is 11 kW at 23.8 A. The 25 A figure is the continuous current limit for motor full-load amps.

MPN
3ABD00049995-D