The ABB 3ABD00050474 is an ACS380-040S-06A9-2 LV AC machinery drive module, rated for 1.1 kW normal-use output at 6.9 A on a 200-240 V three-phase supply. The IE2 efficiency class matches the baseline for fixed-speed motor replacement in European Ecodesign zones.
Normal-use rating is 1.1 kW / 6.9 A; heavy-duty use drops to 0.75 kW / 4.8 A. That heavy-duty figure governs continuous operation on a constant-torque load like a conveyor or positive-displacement pump. Light-overload use (1.1 kW / 6.6 A) covers variable-torque fans and centrifugal pumps where peak demand stays short. Pick the duty cycle that matches your actual load profile — the normal-use number alone can overstate the margin for a high-starting-torque application.
Integration notes
IP20 enclosure requires installation inside a cabinet. Open-type NEMA enclosure means no conduit knockouts — plan for gland-plate entry on the panel bottom.