It delivers 0.55 kW normal-use output at 1.8 A, with a heavy-duty rating of 0.37 kW at 1.2 A. Input accepts 380-480 V 3-phase at 47.5-63 Hz, and the unit is IP20 protected in an open-type NEMA enclosure.
Frame size R0 is the smallest frame for this power band. The normal-use current of 1.8 A is the number to size motor cables and branch protection for continuous duty. If the application cycles hard or runs at high ambient, the heavy-duty rating (1.2 A, 0.37 kW) is the safer design target. Efficiency is IE2, which meets the baseline for most industrial installations in regions not yet requiring IE3 for this power class. The wide input frequency range (47.5-63 Hz) means it works on 50 Hz or 60 Hz supplies without derating.