ABB 3ABD00057879 — AC Drive (VFD) 480V

ABB 3ABD00057879 ACS380 Drive Module, 1.5 kW, 4.0 A, Frame R

MPN3ABD00057879
Active

ABB ACS380-040C-04A0-4+K490+L515+L535, LV AC machinery drive module, Frame Size R1, 380-480 V 3-phase, 47.5-63 Hz, 1.5 kW / 4.0 A normal use, IP20, Open Type, IE2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00057879 — Power & Output
ParameterValue
Output power, normal duty1.5 kW
Output current, normal duty4.0 A
Output power, heavy duty1.1 kW
Output current, heavy duty3.3 A
Output power, light overload1.5 kW
Output current, light overload3.8 A
Efficiency class (IE)IE2
3ABD00057879 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00057879 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Product details

The ABB 3ABD00057879 is a 3-phase LV AC machinery drive in Frame Size R1, rated for 380-480 V input at 47.5-63 Hz. Normal-use output is 1.5 kW at 4.0 A; heavy-duty use drops to 1.1 kW at 3.3 A. Light-overload use matches the normal-use power at 1.5 kW but with a slightly lower current of 3.8 A. The module is IP20, Open Type, and carries IE2 efficiency.

Mounts as a module; Frame Size R1 determines the physical footprint for panel layout and DIN-rail or backplate planning. The IP20 enclosure suits clean, dry cabinet environments — no gland plate sealing required, but keep it away from washdown zones. Input voltage covers 380-480 V three-phase, which covers most European and North American industrial mains without a transformer.

The normal-use rating (1.5 kW, 4.0 A) applies to standard constant-torque loads like conveyors or pumps. The heavy-duty rating (1.1 kW, 3.3 A) is the one to use for variable-torque or high-starting-torque applications — it's the lower current limit that governs when the motor demands more at low speed. If your load profile is mostly light, the light-overload rating (1.5 kW, 3.8 A) gives you the same power but at a slightly reduced current, which can save on cabling or fuse sizing.

Frequently asked questions

What is 3ABD00057879's listed frame size?

The frame size is R1, which determines the physical mounting dimensions and panel space needed.

What are the normal-use and heavy-duty output ratings?

Normal use: 1.5 kW at 4.0 A. Heavy-duty use: 1.1 kW at 3.3 A. Light-overload use: 1.5 kW at 3.8 A.

MPN
3ABD00057879