Skip to main content
ABB 3ABD00057894 — AC Drive (VFD) 480V

ABB 3ABD00057894 ACS380 Drive Module, 2.2 kW, 5.6 A

MPN3ABD00057894
Active

ABB ACS380 series, LV AC machinery drive module, 3ABD00057894, 2.2 kW / 5.6 A normal use, 380-480 V 3-phase, IP20, R1 frame.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00057894 — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty5.6 A
Output power, heavy duty1.5 kW
Output current, heavy duty4.0 A
Output power, light overload2.2 kW
Output current, light overload5.3 A
Efficiency class (IE)IE2
3ABD00057894 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00057894 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Product details

The 3ABD00057894: Normal-use (Pn) lands at 2.2 kW / 5.6 A — that's the continuous rating for a typical constant-torque fan or pump load. Heavy-duty (PhD) derates to 1.5 kW / 4.0 A, which is the figure to use for a conveyor or extruder with sustained overload demand. Light-overload (PlD) stays at 2.2 kW but current drops to 5.3 A, reflecting a slightly different thermal model for intermittent duty. Pick the duty column that matches your load profile; the heavy-duty number is the conservative one for sizing the branch circuit.

Supply and frequency range

Input accepts 380 to 480 VAC three-phase, 47.5 to 63 Hz.

R1 frame, module-style mounting. IP20 enclosure — suitable for a clean indoor panel or cabinet; no washdown or dust rating. Open-type NEMA means it expects enclosure ventilation; don't dead-pack it in a sealed box without airflow.

Listed as current production — no LTB or phase-out on this code. Quoted to order; typical lead time is confirmed at RFQ. If you're freezing a BOM, this one isn't going anywhere soon.

Frequently asked questions

What is the frame size of 3ABD00057894?

Frame size R1.

What input voltage and frequency does this drive accept?

380 to 480 V three-phase, 47.5 to 63 Hz.

What is the normal-use output rating?

2.2 kW at 5.6 A.

What efficiency level is this drive rated for?

IE2.

MPN
3ABD00057894