The 3ABD00057894: Normal-use (Pn) lands at 2.2 kW / 5.6 A — that's the continuous rating for a typical constant-torque fan or pump load. Heavy-duty (PhD) derates to 1.5 kW / 4.0 A, which is the figure to use for a conveyor or extruder with sustained overload demand. Light-overload (PlD) stays at 2.2 kW but current drops to 5.3 A, reflecting a slightly different thermal model for intermittent duty. Pick the duty column that matches your load profile; the heavy-duty number is the conservative one for sizing the branch circuit.
Supply and frequency range
Input accepts 380 to 480 VAC three-phase, 47.5 to 63 Hz.
R1 frame, module-style mounting. IP20 enclosure — suitable for a clean indoor panel or cabinet; no washdown or dust rating. Open-type NEMA means it expects enclosure ventilation; don't dead-pack it in a sealed box without airflow.
Listed as current production — no LTB or phase-out on this code. Quoted to order; typical lead time is confirmed at RFQ. If you're freezing a BOM, this one isn't going anywhere soon.