Skip to main content
ABB 3ABD00057917 — AC Drive (VFD) 480V

ABB 3ABD00057917 ACS380 Drive Module, 22 kW, 50 A, R4

MPN3ABD00057917
Active

ABB ACS380 machinery drive module, 3ABD00057917, Frame R4, 22 kW / 50.0 A normal duty, 380–480 VAC 3-phase, IP20, IE2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00057917 — Power & Output
ParameterValue
Output power, normal duty22 kW
Output current, normal duty50.0 A
Output power, heavy duty22.0 kW
Output current, heavy duty45.0 A
Output power, light overload22.0 kW
Output current, light overload48.0 A
Efficiency class (IE)IE2
3ABD00057917 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00057917 — Mechanical & Cooling
ParameterValue
Frame sizeR4
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule

Product details

The ABB 3ABD00057917 is an ACS380-040C-050A-4+K491+L535 machinery drive module rated 22 kW normal-duty output at 50.0 A, with heavy-duty capability at 45.0 A. It runs on 380–480 V three-phase input, 47.5–63 Hz, and ships in Frame R4 with IP20 open-type enclosure. Efficiency class IE2. Active lifecycle — no phase-out notice on this line.

Ratings & fit

Normal-duty 50.0 A covers most constant-torque loads up to 22 kW. Heavy-duty 45.0 A is the number to use for a 22 kW pump or fan with light overload — the power figure stays the same but the current limit drops, so verify your motor's full-load amps against the 45 A ceiling if you expect occasional overload cycles. Light-overload rating is 48.0 A, slotting between the two.

Listed as Active. This is a current-production ACS380 variant — no last-time-buy window, no successor code to track.

Frequently asked questions

What is the frame size of this drive module?

Frame R4.

What input frequency range does it accept?

47.5 to 63 Hz.

What are the normal-duty and heavy-duty current ratings?

Normal-duty output current is 50.0 A; heavy-duty is 45.0 A. Both at 22 kW output power.

MPN
3ABD00057917