The 3ABD00058230: The normal-duty rating of 15 kW / 32.0 A is the continuous output for typical constant-torque loads such as conveyors or fans. The heavy-duty rating of 11 kW / 25.0 A applies when the drive must handle higher peak torque or more demanding acceleration profiles — that lower current figure reflects the thermal headroom needed for sustained overload.
Integration notes