Skip to main content
ABB 3ABD00058693-D — AC Drives (VFD)

ABB 3ABD00058693-D ACH531-01 HVAC Drive, 4 kW, 9.4 A, R1

MPN3ABD00058693-D
Active

ABB ACH531-01-09A5-4+P973, LV AC wall-mounted HVAC drive, 4 kW normal duty, 9.4 A output current, 380-500 V 3-phase input, IP20 open type, R1 frame size.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical

3ABD00058693-D — Electrical
ParameterValue
Input voltage380 ... 500 V
Frequency47.5 ... 63 Hz
Number of phases3-phase

Power & Current

3ABD00058693-D — Power & Current
ParameterValue
Output power, normal duty4 kW
Output power, light-overload duty4 kW
Output current, normal duty9.4 A
Output current, light-overload duty8.9 A

Protection & Environmental

3ABD00058693-D — Protection & Environmental
ParameterValue
Degree of protection (IP)IP20
NEMA enclosure typeOpen Type

Mechanical

3ABD00058693-D — Mechanical
ParameterValue
Frame sizeR1
Mounting typeWall-mounted

Product details

The 3ABD00058693-D: This is the ACH531-01-09A5-4+P973, a low-voltage AC wall-mounted drive from the ACH531 HVAC series. It delivers 4 kW normal duty at 9.4 A output, with light-overload capability at 8.9 A. Input is 380-500 V three-phase, 47.5-63 Hz. The R1 frame size keeps it compact for panel mounting, and the IP20 open-type enclosure suits clean indoor environments — not the pit floor, but fine in a mechanical room or rooftop unit cabinet.

The 4 kW normal-duty rating at 9.4 A tells you this drive handles a standard 4-pole induction motor up to that power on 400 V supply. The light-overload figure of 8.9 A is slightly lower — that's the continuous current for variable-torque loads like fans and pumps where peak demand stays under the normal-duty curve. The 380-500 V input range covers 400 V and 480 V grids; the 47.5-63 Hz frequency acceptance handles 50 Hz and 60 Hz systems without a configuration change. Frame R1 means it fits the compact footprint typical for this power class — check the mounting dimensions against your panel layout before committing the cutout.

Frequently asked questions

What is the frame size of this drive?

It is listed as Frame Size R1, which is the compact physical footprint for this power class in the ACH531 series.

What are the key electrical ratings for this drive?

Normal duty output is 4 kW at 9.4 A; light-overload output is 4 kW at 8.9 A. Input voltage is 380-500 V three-phase, 47.5-63 Hz.

What enclosure protection does this drive have?

It carries IP20 protection with an open-type NEMA enclosure, suitable for indoor installation in clean, dry environments.

MPN
3ABD00058693-D