Skip to main content
ABB 3ABD00058711-D — AC Drives (VFD)

ABB 3ABD00058711-D LV AC Drive, Frame R1, 0.75 kW, 2.6 A

MPN3ABD00058711-D
Active

ABB LV AC wall-mounted drive, Frame R1, 0.75 kW, 2.6 A, 380-500 V, 3-phase, IP20, NEMA Open Type.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Electrical

3ABD00058711-D — Electrical
ParameterValue
Input voltage380 ... 500 V
Frequency47.5 ... 63 Hz
Number of phases3-phase

Power & Current

3ABD00058711-D — Power & Current
ParameterValue
Output power, normal duty0.75 kW
Output power, light-overload duty0.75 kW
Output current, normal duty2.6 A
Output current, light-overload duty2.5 A

Protection & Environmental

3ABD00058711-D — Protection & Environmental
ParameterValue
Degree of protection (IP)IP20
NEMA enclosure typeOpen Type

Mechanical

3ABD00058711-D — Mechanical
ParameterValue
Frame sizeR1
Mounting typeWall-mounted

Product details

The ABB 3ABD00058711-D is a low-voltage AC wall-mounted drive in Frame R1, rated 0.75 kW normal-use output at 2.6 A, with light-overload capability at 0.75 kW and 2.5 A. It accepts 380-500 V three-phase input across 47.5-63 Hz, and carries IP20 protection in a NEMA Open Type enclosure.

The normal-use current of 2.6 A at 0.75 kW is the rating that governs motor sizing — it matches a standard 1 hp (0.75 kW) induction motor on 400 VAC. The light-overload current (2.5 A) is essentially the same curve, so the drive doesn't give you extra headroom for short-duration overloads; it's sized for continuous HVAC duty. Frame R1 means the drive body is compact enough to mount on a wall plate or inside a small panel, but the IP20 rating says keep it in a clean environment — no washdown or outdoor exposure.

Mounting & wiring notes

Wall-mounted, open type — no separate enclosure needed if the drive sits in a controlled electrical room. The 47.5-63 Hz frequency acceptance means it handles 50 Hz and 60 Hz supplies without configuration. Three-phase input, so land, L2, L3; the motor output terminals connect to the motor leads. Ground bond per local code; use a torque driver on the power terminals — the frame R1 terminal block is small, and overtightening strips the threads.

Frequently asked questions

What is the frame size of this drive?

Frame R1 — the smallest mechanical size in the ACH531 series, suitable for 0.75 kW output.

What compliance documentation is available?

The drive is listed as a standard ABB LV AC drive; RoHS, REACH, and CE documentation is typically provided with the shipment. Specific UL or IEC certificates should be confirmed at time of order.

MPN
3ABD00058711-D