The 3ABD00059194-D: Output current at light-overload use is 12 A, close to the normal-use 12.6 A — the drive is sized for continuous duty at nameplate. Frequency range 47.5-63 Hz covers 50/60 Hz grids without derating. The R1 frame keeps the footprint compact for a 5.5 kW wall-mount unit; verify gland-plate clearance if replacing an older larger-frame drive.
No PCN or last-time-buy window to track.