ABB 3ABD00059227-D — AC Drive (VFD) 480V

ABB 3ABD00059227-D ACS530-04-650A-4+P972, 355 kW / 650 A

MPN3ABD00059227-D
Active

ABB ACS530-04-650A-4+P972, 3-phase, 380-480 V, 47.5-63 Hz, 355 kW normal use, 650 A output, frame R10, open type IP00.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ABD00059227-D — Power & Output
ParameterValue
Output power, normal duty355 kW
Output current, normal duty650 A
Output power, light overload355 kW
Output current, light overload634 A
3ABD00059227-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00059227-D — Mechanical & Cooling
ParameterValue
Frame sizeR10
NEMA enclosure typeOpen Type
Degree of protection (IP)IP00
Mounting typeCabinet-built

Product details

The ABB 3ABD00059227-D is an ACS530-04-650A-4+P972 drive rated for 355 kW normal use at 650 A output, 380-480 V three-phase input, 47.5-63 Hz. Frame size R10, open type (IP00) — cabinet-built, no unit enclosure. This is a current-production part, actively available.

Normal-use output current (650 A) and power (355 kW) match the drive's continuous motor rating. Light-overload duty also holds at 355 kW with 634 A — same power, slightly lower current, meaning the drive is sized for constant-torque loads at full rating without headroom for heavy overload cycling. For a pump or fan application this is fine; for a crusher or extruder with short-term peak demands, check the actual overload profile against the drive's thermal model.

Installation context

Open-type IP00 means the drive must be mounted inside a suitable cabinet with proper cooling and IP rating for the environment. Frame R10 determines mounting dimensions and bus-bar / cable entry layout — verify cabinet cutout and bus bar spacing against the ACS530 hardware manual before panel layout.

Frequently asked questions

What are the key electrical ratings for this drive?

Normal use: 355 kW output power at 650 A, light-overload: 355 kW at 634 A. Input voltage 380-480 V three-phase, 47.5-63 Hz.

What frame size is 3ABD00059227-D?

Frame size R10.

What enclosure type and protection rating does this drive have?

Open type (NEMA Open) with IP00 degree of protection — it is a cabinet-built unit, not a standalone enclosed drive.

MPN