Specifications

3ABD00059228-D — Power & Output
ParameterValue
Output power, normal duty400 kW
Output current, normal duty725 A
Output power, light overload400 kW
Output current, light overload715 A
3ABD00059228-D — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3ABD00059228-D — Mechanical & Cooling
ParameterValue
Frame sizeR11
NEMA enclosure typeOpen Type
Degree of protection (IP)IP00
Mounting typeCabinet-built

Product details

The 3ABD00059228-D: This ABB ACS530-04-725A-4+P972 is a 400 kW drive module in frame size R11, rated for 725 A continuous output on a 380-480 V three-phase supply. That 725 A number is the heavy lifting spec — it tells you the drive can hold that current indefinitely into a motor load without tripping on thermal overload. The IP00 open-type enclosure means it's meant for a cabinet, not standalone floor mounting; you'll need to provide the enclosure and cooling airflow. Input frequency range spans 47.5 to 63 Hz, so it handles both 50 Hz and 60 Hz grids without reconfiguration. That's a standard fit for most industrial sites globally, but worth noting if your plant runs on a non-standard frequency.

Integration notes

The light-overload rating is 715 A at 400 kW, slightly lower than the normal-use 725 A. If your application runs the motor hard for extended periods — say a conveyor or pump running near full load — the 725 A normal-use figure is the one to design to. The light-overload figure matters if you need short bursts above rated current for starting or intermittent overloads. Frame size R11 tells you the physical footprint and mounting pattern. It's a larger frame, as you'd expect for a 400 kW drive. Make sure your cabinet has the depth and ventilation to handle the heat dissipation — an IP00 unit relies on cabinet airflow, not its own fan.

Frequently asked questions

What are the key ratings for this drive?

400 kW output power, 725 A continuous output current (normal use), 380-480 V three-phase input, frame size R11, IP00 open type.

What input frequency range does it support?

47.5 to 63 Hz, covering both 50 Hz and 60 Hz grids.

How do I source this part?

It's an active product, so we can quote it to order against an RFQ. No special surplus or last-time-buy arrangements needed.

MPN