Frame size R10, IP20 open-type enclosure — this is the module that lands in the cabinet, not the full drive cabinet itself.
Three duty curves are documented: normal use at 630 kW / 650 A, heavy-duty at 560 kW / 571 A, and light-overload at 630 kW / 630 A. Light-overload matches normal-use power but drops current to 630 A, which matters when the application cycles above baseline.