The 3ABD00059358-D is an ABB ACQ531 drive, order code ACQ531-04-820A-4+P974, in Frame R11. It delivers 450 kW normal-use output at 820 A, with light-overload rated 450 kW at 810 A — the slight current difference tells you the drive is sized for continuous duty at nameplate, not for short-term overload headroom. Input is 380-480 V three-phase, 47.5-63 Hz. The IP00 open-type enclosure means it goes into a cabinet; no onboard protection against dust or splash.

3ABD00059358-D ACQ531 drive, 450 kW, 820 A, Frame R11
MPN3ABD00059358-D
Active
ABB ACQ531 series, ACQ531-04-820A-4+P974, Frame R11, 450 kW normal-use output, 820 A, 380-480 V 3-phase, IP00, IE2.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Output power, normal duty | 450 kW |
| Output current, normal duty | 820 A |
| Output power, light overload | 450 kW |
| Output current, light overload | 810 A |
| Efficiency class (IE) | IE2 |
| Parameter | Value |
|---|---|
| Input voltage range | 380 ... 480 V |
| Number of phases | 3-phase |
| Frequency | 47.5 ... 63 Hz |
| Parameter | Value |
|---|---|
| Frame size | R11 |
| NEMA enclosure type | Open Type |
| Degree of protection (IP) | IP00 |
| Mounting type | Module |
Product details
Frequently asked questions
What is the frame size and what does it mean for installation?
Frame R11 is the mechanical footprint. This is a large drive — the R11 frame typically requires a floor-standing cabinet and busbar connections. Verify cabinet depth and busbar rating against the 820 A output current.
What are the key electrical ratings?
Normal-use output: 450 kW at 820 A. Light-overload: 450 kW at 810 A. Input: 380-480 V three-phase, 47.5-63 Hz. Efficiency level IE2.
MPN