Skip to main content
ABB 3ABD00059572-D — AC Drive (VFD) 600V

ABB 3ABD00059572-D ACS880-01 Drive, 110 kW, 119 A, Frame R7

MPN3ABD00059572-D
Active

ABB ACS880-01, wall-mounted, 3-phase, 525–690 V input, 110 kW / 119 A normal duty, frame size R7, IP21, position control variant.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ABD00059572-D — Identification
ParameterValue
Frame sizeR7
3ABD00059572-D — Electrical (input)
ParameterValue
Input voltage range525 ... 690 V
Number of phases3-phase
Frequency range48 ... 63 Hz
3ABD00059572-D — Output / Performance
ParameterValue
Output power, normal duty110 kW
Output power, heavy duty90 kW
Output power, light overload110 kW
Output current, normal duty119 A
Output current, heavy duty98 A
Output current, light overload113 A
3ABD00059572-D — Mechanical
ParameterValue
Mounting typeWall-mounted
NEMA enclosure typeOpen Type
3ABD00059572-D — Environmental
ParameterValue
Degree of protection (IEC, IP)IP21

Product details

The 3ABD00059572-D: The normal-duty 110 kW / 119 A rating suits variable-torque applications like pumps and fans. The heavy-duty 90 kW / 98 A rating is the one to use for constant-torque loads such as conveyors or extruders where starting current and sustained torque are higher. Light-overload use is rated at 110 kW / 113 A. If your motor is sized for heavy-duty, the 90 kW figure governs the selection — not the 110 kW headline.

Wall-mounted, open-type NEMA enclosure with IP21 protection — suitable for indoor, clean environments. The 525–690 V input range means it is intended for 690 V class systems.

Frequently asked questions

What is the frame size of this drive?

Frame size R7, which determines the physical mounting dimensions and enclosure layout.

What input voltage does this drive require?

525–690 V AC, 3-phase, 48–63 Hz.

What are the normal-duty and heavy-duty ratings?

Normal duty: 110 kW / 119 A. Heavy duty: 90 kW / 98 A. Light overload: 110 kW / 113 A.

Does this drive include position control?

Yes, the order code includes the D150+N5700 position control option, factory-integrated.

MPN
3ABD00059572-D