Sizing and duty ratings
The 3ABD00059672-D: Normal-duty output is 250 kW / 271 A; heavy-duty drops to 200 kW / 210 A. Light-overload rating matches normal at 250 kW / 257 A. The heavy-duty figure is the one to use for constant-torque loads like conveyors or extruders — the 210 A limit governs the thermal capacity under sustained overload.
Lifecycle and sourcing
Listed as current production — no end-of-life notice. Sourced to order against an RFQ; lead time confirmed at time of quote. No official successor or cross-reference exists; this is the active variant.