Duty ratings and motor match
The 3ABD00059688: Normal-use (Pn) lands at 2.2 kW / 5.6 A — that is the continuous rating for a standard 4-pole induction motor on a pump or fan. Heavy-duty (PhD) drops to 1.5 kW / 4.0 A, which is the figure to use for constant-torque loads like a conveyor or extruder where the drive must hold current through a stall cycle. Light-overload (PlD) matches the normal-use power at 2.2 kW but current is trimmed to 5.3 A; that slight derate reflects the IEC light-overload curve. Pick your load profile before you commit the BOM line — the heavy-duty number is the safe one for applications with intermittent peak torque.
Mains and enclosure
Input voltage range 380–480 VAC, frequency 47.5–63 Hz. IP20 open-type enclosure. Three-phase input only.
Efficiency class
Rated IE2 efficiency.
Product status is active. Frame R1 is current-production.