Skip to main content
ABB 3ADT218042S0234 — AC Drive (VFD) 600V

ABB 3ADT218042S0234 DCS880 DC Converter, 2500 A, 690 VAC, H7

MPN3ADT218042S0234
Active

ABB DCS880-S02-2500-07, 4Q DC converter, 690 VAC, 2500 A, Frame Size H7.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ADT218042S0234 — Identification
ParameterValue
Frame sizeH7
3ADT218042S0234 — Electrical (input)
ParameterValue
Frequency range50 Hz
3ADT218042S0234 — Environmental
ParameterValue
Degree of protection (IEC, IP)acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00
3ADT218042S0234 — Other specifications
ParameterValue
Sound75 dB(A)
Analog inputs3
Analog outputs2
Operating humidity (RHamβ)5...95%

Product details

The ABB 3ADT218042S0234 is a DCS880-S02-2500-07 DC converter, a 4-quadrant regenerative unit rated for 2500 A at 690 VAC. Frame size H7. This is the drive section for a large DC motor armature or field supply in applications requiring full four-quadrant control — motoring and regenerative braking in both directions.

Auxiliary terminals are rated IP00 per IEC 60529 and IEC 60947-1, meaning no ingress protection on those connection points — they require enclosure in a panel or cabinet with at least IP2X on the gland plate. Operating humidity range is 5 to 95% RH, non-condensing. The unit emits 75 dB(A) under load, which may dictate acoustic enclosure placement in noise-sensitive environments. Three analog inputs and two analog outputs are available for speed/current reference and actual-value feedback. The converter is designed for 50 Hz line frequency.

Frequently asked questions

What is the frame size of this DC converter?

Frame size H7, which determines the physical mounting, busbar connections, and cooling duct interface.

What are the key electrical ratings?

Continuous current 2500 A at 690 VAC input, 4-quadrant regenerative operation. Three analog inputs and two analog outputs are standard.

What is the sound level of this unit?

75 dB(A) under load, which may require acoustic enclosure planning in noise-sensitive areas.

What ingress protection does it have?

Auxiliary terminals are rated IP00 per IEC 60529 and IEC 60947-1, requiring enclosure within a panel or cabinet.

MPN
3ADT218042S0234