Skip to main content
ABB 3ADT218566S0144 — AC Drive (VFD) 600V

3ADT218566S0144 ABB DCS880-S01-4000-07L DC Converter, 690 VA

MPN3ADT218566S0144
Active

ABB DCS880-S01-4000-07L DC Converter, 2Q, 690 VAC, 4000 A, Frame Size H8, 82 dB(A), 3 AI / 2 AO.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ADT218566S0144 — Identification
ParameterValue
Frame sizeH8
3ADT218566S0144 — Electrical (input)
ParameterValue
Frequency range50 Hz
3ADT218566S0144 — Environmental
ParameterValue
Degree of protection (IEC, IP)acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00
3ADT218566S0144 — Other specifications
ParameterValue
Sound82 dB(A)
Analog inputs3
Analog outputs2
Operating humidity (RHamβ)5...95%

Product details

The ABB 3ADT218566S0144 is a DCS880-S01-4000-07L DC converter, a 2-quadrant unit rated for 690 VAC input and 4000 A output. It sits in frame size H8, which tells you the mechanical footprint and bus-bar layout you need for panel planning.

The 4000 A rating is the continuous output current — that's the number that decides cable sizing, bus-bar cross-section, and thermal management. The 690 VAC input is the line voltage it's designed for; don't assume it derates gracefully to lower voltages without checking the drive's internal DC-link design. Frame size H8 is a physical envelope: it determines mounting hole pattern, gland-plate clearance, and the minimum cabinet depth. The 82 dB(A) sound level is the audible noise under load — relevant if the drive sits near operator stations or in a noise-controlled area. The 3 analog inputs and 2 analog outputs are the I/O complement on the control board. Enough for a basic speed reference and a couple of feedback signals, but if you need more, you'll add an option module.

This class of DC converter drives DC motors in heavy industrial applications — extruders, winders, cranes, mill drives — where you need controlled torque and speed from a DC motor on a 690 VAC supply. The 2-quadrant design handles motoring in one direction; for regenerative braking you'd step up to a 4Q unit.

Frequently asked questions

What is the frame size of this DC converter?

Frame size H8. That defines the mounting footprint, bus-bar spacing, and cabinet cutout dimensions.

What is the sound level of this drive?

82 dB(A) under load. Factor that into enclosure design if the drive is near operator positions.

How many analog inputs and outputs does it have?

3 analog inputs and 2 analog outputs on the standard control board.

MPN
3ADT218566S0144