ABB 3ADT218566S0236 — DC Drives

3ADT218566S0236 ABB DCS880-S02-3300-10L DC Converter, 3300 A

MPN3ADT218566S0236
Active

ABB DCS880-S02-3300-10L, 4Q DC Converter, 990 VAC, 3300 A, Frame Size H8, 180 kg.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3ADT218566S0236 — Electrical
ParameterValue
Frequency50 Hz
3ADT218566S0236 — I/O
ParameterValue
Analog inputs3
Analog outputs2
3ADT218566S0236 — Environmental
ParameterValue
Degree of protection (IP)acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00
Operating humidity (RH)5...95%
Noise level (dB(A))82 dB(A)
3ADT218566S0236 — Mechanical
ParameterValue
Frame sizeH8

Product details

The 3ADT218566S0236: The 3300 A continuous rating and 4Q (four-quadrant) capability mean this converter handles regenerative loads — overhauling cranes, downhill conveyors, or dynamometer test stands — where the motor feeds power back into the DC bus. The 990 VAC supply side is the nominal three-phase input; verify your line voltage matches before committing the cabinet. Frame size H8 is the physical envelope and thermal class. It determines the mounting hole pattern, busbar connections, and the forced-air or liquid-cooling interface. If you are replacing an existing H8-frame drive, the mechanical fit is direct; if you are retrofitting from a different frame, expect to rework the cabinet floor and ducting. The sound level is 82 dB(A). That is not a selection parameter for most installations, but it matters if the cabinet sits near a quiet zone or operator station — plan for acoustic enclosure or distance. Protection at the auxiliary terminals is IP00 per IEC 60529 and IEC 60947-1. That means no dust or water ingress protection at those connection points — the converter must live inside a panel with a higher overall enclosure rating. The main power terminals may carry a different rating; verify the datasheet for the full unit.

I/O and control interface

The converter carries 3 analog inputs and 2 analog outputs. That is enough for a speed reference, a torque limit, and a feedback transducer on the inputs, plus speed and current signals to a PLC or DCS on the outputs. No digital I/O count is listed here, so if your application needs extensive discrete control, plan for an external I/O block or a fieldbus adapter. Operating humidity range is 5 to 95% RH, non-condensing.

Frequently asked questions

What is the frame size of the 3ADT218566S0236?

The frame size is H8. This determines the physical mounting, busbar layout, and cooling interface for the converter.

What is the sound level of this DC converter?

The sound pressure level is 82 dB(A). This is relevant for installations near operator stations or in noise-sensitive areas.

What compliance documentation is available for the 3ADT218566S0236?

The degree of protection is stated as IP00 at the auxiliary terminals per IEC 60529 and IEC 60947-1. For RoHS, REACH, or UL documentation, request the manufacturer's declaration through an RFQ — those are not listed in the base spec.