ABB 3ADT218567S0242 — DC Drives

3ADT218567S0242 ABB DCS880-S02-4000-05R DC Converter, 525 VA

MPN3ADT218567S0242
Active

ABB DCS880-S02-4000-05R DC Converter, 4Q, 525 VAC, 4000 A, H8 Frame, 82 dB(A), Active.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3ADT218567S0242 — Electrical
ParameterValue
Frequency50 Hz
3ADT218567S0242 — I/O
ParameterValue
Analog inputs3
Analog outputs2
3ADT218567S0242 — Environmental
ParameterValue
Degree of protection (IP)acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP00
Operating humidity (RH)5...95%
Noise level (dB(A))82 dB(A)
3ADT218567S0242 — Mechanical
ParameterValue
Frame sizeH8

Product details

The ABB 3ADT218567S0242 is a DCS880-S02-4000-05R DC converter — a four-quadrant regenerative unit rated for 525 VAC input and 4000 A output. It sits in the H8 frame size, which dictates the cabinet cutout, busbar layout, and cooling ductwork for the installation. This is a 4Q converter, meaning it handles motoring and regenerative braking in both directions of rotation — typical for overhauling loads like unwind stands, hoists, or test benches where energy recovery is part of the cycle.

Sound level is listed at 82 dB(A). That's the audible noise under rated load from the cooling fans and magnetics — relevant for plant siting if the converter lives near an operator station or in a noise-controlled area. Auxiliary terminals carry an IP00 rating per IEC 60529 and IEC 60947-1 — meaning no ingress protection at the terminal block level. The main enclosure will have its own IP rating, but the aux connections expect to be inside a cabinet or otherwise protected from dust and moisture. Operating humidity range is 5 to 95% RH, non-condensing.

Analog I/O onboard

The converter comes with 3 analog inputs and 2 analog outputs as standard. These are available for speed reference, torque limit, or process feedback signals without needing an additional I/O module — useful for a standalone drive installation where the PLC connection is over fieldbus.

Frequently asked questions

What is the frame size for this converter?

The frame size is H8. This determines the physical mounting footprint, busbar arrangement, and cooling requirements for the cabinet design.

What is the sound level of this drive?

The sound level is rated at 82 dB(A) under load, driven primarily by the cooling fans and transformer magnetics.

What is the input voltage and current rating?

It is rated for 525 VAC input and 4000 A output, configured as a 4-quadrant regenerative DC converter.

MPN