Skip to main content
ABB 3AUD0000000035 — AC Drive (VFD) 480V

ABB 3AUD0000000035 HVAC Drive, 125 Hp, 156 A, NEMA 3R

MPN3AUD0000000035
Active

ABB, HVAC packaged drive with e-clipse bypass and disconnect, 3AUD0000000035, 125 Hp, 156 A, 440-480 V, 3-phase, NEMA Type3R, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AUD0000000035 — Input / Supply
ParameterValue
Input voltage range440 ... 480 V
Number of phases3-phase
Frequency50/60 Hz
3AUD0000000035 — Power & Output
ParameterValue
Output current, light overload (UL rating)156 A
Output power, light overload (UL rating, Hp)125 Hp
3AUD0000000035 — Mechanical & Cooling
ParameterValue
NEMA enclosure typeType3R

Product details

HVAC packaged drive with e-clipse bypass and disconnect

The ABB 3AUD0000000035 is an HVAC packaged drive with e-clipse bypass and disconnect, UL-rated for 125 Hp light-overload use at 156 A output current. Same part, different passport — this is the genuine ABB unit, active in production per the manufacturer. Input is 440-480 V three-phase at 50/60 Hz, housed in a NEMA Type3R enclosure — rainproof and sleet-resistant, suitable for outdoor rooftop or pad-mounted HVAC installations without an additional weather hood.

The 156 A continuous output at 125 Hp (light-overload duty per UL) tells you this drive handles a 125 Hp motor on a typical fan or pump curve without derating. Light-overload means 110% current for 60 seconds — enough for centrifugal load starts, not for high-torque conveyors. The NEMA Type3R enclosure means it lives outdoors; no need for a separate cabinet if local code allows. The e-clipse bypass and disconnect integrated into the package means the motor can run across the line if the drive faults — a common requirement for critical HVAC loads like chiller compressors or hospital AHUs where a stopped fan is a bigger problem than a slightly less efficient run.

Frequently asked questions

What is the closest alternative to 3AUD0000000035 in this family?

Within the ACH580-BDR family, the closest sibling would be a different horsepower/current variant — same e-clipse bypass and NEMA 3R construction, same 440-480 V input, just scaled up or down in output current. No pin-compatible drop-in exists at a different rating; the bypass contactor and disconnect sizing change with the frame.

Where can I buy 3AUD0000000035?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time estimate.

What compliance documentation does ABB provide for 3AUD0000000035?

As an ABB HVAC drive with UL listing, the unit carries UL and cUL marks. RoHS and REACH declarations are standard from ABB for this product line. The NEMA Type3R rating is tested per UL 50E.

MPN
3AUD0000000035