Skip to main content
ABB 3AUD0000000037 — AC Drive (VFD) 480V

ABB 3AUD0000000037 HVAC Drive, 200 Hp, 240 A, NEMA 3R

MPN3AUD0000000037
Active

ABB, ACH580 series, HVAC packaged drive with e-clipse bypass and disconnect, 3-phase, 440...480 V, UL: 200 Hp, 240 A light-overload, NEMA 3R enclosure.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AUD0000000037 — Input / Supply
ParameterValue
Input voltage range440 ... 480 V
Number of phases3-phase
Frequency50/60 Hz
3AUD0000000037 — Power & Output
ParameterValue
Output current, light overload (UL rating)240 A
Output power, light overload (UL rating, Hp)200 Hp
3AUD0000000037 — Mechanical & Cooling
ParameterValue
NEMA enclosure typeType3R

Product details

The ABB 3AUD0000000037 is a factory-assembled HVAC packaged drive integrating an ACH580 variable-speed drive with an e-clipse bypass contactor and a disconnect switch, all inside a NEMA 3R enclosure. That means it arrives ready for outdoor or sheltered wall-mount installation — no separate bypass cabinet or field wiring of the bypass contactor. The 240 A continuous rating at light-overload (UL) corresponds to 200 Hp on a typical 460 V motor, sized for large centrifugal fans, pumps, or cooling towers in commercial HVAC plants.

Voltage, phases, and frequency — what the line needs

Input voltage range is 440 to 480 V, three-phase, 50/60 Hz. That covers the common North American 460 V and 480 V distribution systems as well as 50 Hz grids. The NEMA 3R enclosure protects against rain and sleet but is not rated for hose-down or submersion — suitable for rooftop or exterior wall mounting where the drive sees weather but not washdown.

This is a current-production catalog item, not a phase-out or last-time-buy.

Frequently asked questions

What is the closest alternative to 3AUD0000000037 in the ACH580 family?

The closest sibling would be a standard ACH580 drive without the factory-integrated e-clipse bypass and disconnect. That requires separate bypass contactor and disconnect wiring in the field. The 3AUD0000000037 saves panel space and installation labor by combining all three functions in one NEMA 3R package.

What are the key ratings for 3AUD0000000037?

UL light-overload output is 240 A continuous, 200 Hp at 460 V. Input is 440–480 V, 3-phase, 50/60 Hz. Enclosure is NEMA 3R for outdoor sheltered use.

Where can I buy 3AUD0000000037 and get current pricing?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

MPN
3AUD0000000037