Skip to main content
ABB 3AUD0000000072 — AC Drive (VFD) 480V

ABB 3AUD0000000072 HVAC Drive, 350 Hp, 414 A, NEMA 3R

MPN3AUD0000000072
Active

ABB ACH580-series HVAC drive with integrated circuit breaker disconnect, 3-phase 380-480 V, UL light-overload 350 Hp / 414 A, NEMA Type 3R enclosure, 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AUD0000000072 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency50/60 Hz
3AUD0000000072 — Power & Output
ParameterValue
Output current, light overload (UL rating)414 A
Output power, light overload (UL rating, Hp)350 Hp
3AUD0000000072 — Mechanical & Cooling
ParameterValue
NEMA enclosure typeType3R

Product details

The ABB 3AUD0000000072 is an ACH580-series HVAC drive with an integrated circuit breaker disconnect, rated for 3-phase 380-480 V input at 50/60 Hz. Its UL light-overload rating of 350 Hp / 414 A means it can continuously supply a 3-phase induction motor of that size on a fan or pump curve without needing to oversize the drive for the starting current — the integrated breaker handles the branch-circuit protection upstream, so you skip a separate disconnect in the enclosure.

NEMA Type 3R enclosure means this unit is rated for outdoor installation — rain-tight, sleet-resistant, and the enclosure won't corrode under a roof eave or on a rooftop pad. No separate weather hood needed for most commercial HVAC rooftop applications. The integrated circuit breaker disconnect is a single assembly; mount the drive, land the line-side power on the breaker lugs, and the load-side conductors terminate directly on the drive output bus.

Frequently asked questions

What is the input voltage and frequency for 3AUD0000000072?

Rated for 3-phase 380-480 V input at 50/60 Hz. The wide voltage window covers both 400 V and 480 V nominal systems without a reconnection tap.

What is the UL light-overload rating for this drive?

UL light-overload rating is 350 Hp / 414 A. This is the continuous output capacity for variable-torque HVAC loads (fans, centrifugal pumps) under UL listing.

Where can I buy 3AUD0000000072?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
3AUD0000000072