Skip to main content
ABB 3AUD0000000121 — AC Drive (VFD) 240V

ABB 3AUD0000000121 ACH580 HVAC Drive, 100 Hp, 273 A, 208-240

MPN3AUD0000000121
Active

ABB ACH580 HVAC packaged drive, 3AUD0000000121, with e-clipse bypass and disconnect, UL: 100 Hp, 273 A light-overload, 208-240 V 3-phase, NEMA Type 3R, 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AUD0000000121 — Electrical Input
ParameterValue
Input voltage range208 ... 240 V
Number of phases3-phase
Frequency50/60 Hz
3AUD0000000121 — Electrical Output
ParameterValue
Output power, light-overload duty (UL, Hp)100 Hp
Output current, light-overload duty (UL)273 A
3AUD0000000121 — Mechanical
ParameterValue
Enclosure type (NEMA)Type3R

Product details

The ABB 3AUD0000000121 is an ACH580-series HVAC packaged drive with an integrated e-clipse bypass and disconnect switch. It's UL rated for 100 Hp light-overload use at 273 A output, on a 208-240 V three-phase supply (50/60 Hz). The NEMA Type 3R enclosure means it's built for outdoor or unconditioned indoor installation — rain-tight and sleet-resistant, no additional weather cover needed. This is a single-assembly solution for a rooftop unit or air handler: the bypass lets the motor run directly off line power if the drive faults, so the building doesn't lose airflow while you troubleshoot.

Lifecycle status is active — this is a current-production catalog item, not a phase-out or NRND line. The ACH580 platform is ABB's dedicated HVAC drive family, and the e-clipse bypass variant is a standard offering for packaged solutions.

The 273 A light-overload rating (UL) governs the real motor load this drive can handle continuously for a variable-torque HVAC fan or pump. Light-overload (110% for 60 s) is the standard duty cycle for centrifugal loads — a 100 Hp motor at full load draws roughly that current, so the drive is sized correctly for a 100 Hp fan without oversizing. The 208-240 V input range is narrow; if your site feeds 480 V, this is the wrong unit — you'd need the 480 V variant in the ACH580 family. The NEMA 3R enclosure eliminates the need for a separate rain hood, but it's not a washdown enclosure; keep it out of direct hose spray.

Frequently asked questions

What is the input voltage and phase requirement for 3AUD0000000121?

It requires 208-240 V three-phase input at 50/60 Hz. Single-phase supply is not supported.

What enclosure type is 3AUD0000000121?

NEMA Type 3R — rain-tight and sleet-resistant, suitable for outdoor installation without an additional weather cover.

Where can I buy 3AUD0000000121?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the UL output rating of 3AUD0000000121?

UL rated 100 Hp light-overload use at 273 A output current, on a 208-240 V three-phase supply.

MPN
3AUD0000000121