Skip to main content
ABB 3AUD0000000141 — AC Drive (VFD) 240V

3AUD0000000141 HVAC Drive, 100 Hp, 273 A, NEMA 3R

MPN3AUD0000000141
Active

ABB ACH580 series HVAC drive with integrated circuit breaker disconnect, UL rated 100 Hp light-overload, 273 A output, 208-240 V 3-phase, NEMA Type 3R enclosure, 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AUD0000000141 — Electrical Input
ParameterValue
Input voltage range208 ... 240 V
Number of phases3-phase
Frequency50/60 Hz
3AUD0000000141 — Electrical Output
ParameterValue
Output power, light-overload duty (UL, Hp)100 Hp
Output current, light-overload duty (UL)273 A
3AUD0000000141 — Mechanical
ParameterValue
Enclosure type (NEMA)Type3R

Product details

The 3AUD0000000141 is an ABB ACH580-series HVAC drive with an integrated circuit breaker disconnect, UL-listed for 100 Hp light-overload use at 273 A output current. Input is 208-240 V three-phase, 50/60 Hz, so it fits standard North American low-voltage commercial supply without a step-down transformer. The NEMA Type 3R enclosure means it is rated for outdoor installation — rain-tight and sleet-resistant — suitable for rooftop HVAC units or wall-mount outside the equipment room.

The integrated circuit breaker disconnect simplifies panel layout by combining the drive and branch-circuit protection into one enclosure — one line-up, one nameplate to verify against the UL 508A assembly.

Integration note

The NEMA 3R enclosure is rainproof but not dust-tight; if the installation sees airborne particulates (grain dust, concrete fines), plan a filtered intake or locate the drive inside a separate cabinet. At 273 A light-overload output, the drive will require appropriately sized copper conductors and a disconnect capable of interrupting that current — the built-in breaker handles that, but the incoming feeder must be rated for the full-load amps plus any derating for conduit fill and ambient temperature.

Frequently asked questions

What is the output power rating of 3AUD0000000141?

UL-listed for 100 Hp light-overload use, with a corresponding output current of 273 A.

Where can I buy 3AUD0000000141?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What enclosure type does 3AUD0000000141 have?

NEMA Type 3R, which is rain-tight and sleet-resistant, making it suitable for outdoor installation.

MPN
3AUD0000000141