Skip to main content
ABB 3AUD0000000679 — AC Drive (VFD) 480V

ABB 3AUD0000000679 HVAC Drive, 40 Hp, 52 A, 460 V

MPN3AUD0000000679
Active

ABB HVAC packaged ultra-low harmonic drive, 3AUD0000000679, R6 frame, 40 Hp, 52 A, 460 V, 3-phase, 50/60 Hz, IP21, NEMA Type 1.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AUD0000000679 — Input / Supply
ParameterValue
Input voltage range440 ... 480 V
Number of phases3-phase
Frequency50/60 Hz
3AUD0000000679 — Power & Output
ParameterValue
Output current, light overload (UL rating)52 A
Output power, light overload (UL rating, Hp)40 Hp
3AUD0000000679 — Mechanical & Cooling
ParameterValue
Frame sizeR6
NEMA enclosure typeType1
Degree of protection (IP)IP21

Product details

The ABB 3AUD0000000679 is an HVAC packaged ultra-low harmonic drive with an integrated circuit breaker, built for 3-phase 440–480 VAC supplies. It delivers 40 Hp at 52 A under light-overload (UL) duty — the rating that governs continuous fan and pump loads in commercial HVAC. The R6 frame houses the harmonic filter and breaker in a single IP21 / NEMA Type 1 enclosure, so it mounts indoors without a separate filter cabinet.

The 52 A light-overload current (UL) is the continuous rating for variable-torque loads — fans, centrifugal pumps, compressors. That 40 Hp at 460 V maps to a standard NEMA motor frame; if your BOM calls for 40 Hp at 480 V, this drive covers it without oversizing. The integrated circuit breaker saves a panel slot and simplifies coordination — no separate branch-circuit protection to size and wire. IP21 means the drive is drip-proof but not washdown-rated; keep it in a conditioned electrical room, not on the production floor.

Integration notes

The R6 frame is a floor-standing or wall-mount package; plan for bottom cable entry and overhead clearance for the integrated breaker handle. The drive accepts 50/60 Hz line frequency — no derating needed for 50 Hz installations. NEMA Type 1 means no additional enclosure for dry indoor locations; if the room sees condensation, add a space heater or relocate to a Type 12 cabinet.

Frequently asked questions

What is the frame size of 3AUD0000000679?

The frame size is R6, which is a floor-standing or wall-mount enclosure for the integrated drive, harmonic filter, and circuit breaker.

What is the output power rating of this drive?

Under UL light-overload conditions, the drive is rated for 40 Hp at 52 A output current on a 460 V supply.

Where can I buy 3AUD0000000679?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability; we confirm both at quote time.

MPN
3AUD0000000679