Skip to main content
ABB 3AUD0000000714 — AC Drive (VFD) 480V

ABB 3AUD0000000714 HVAC Drive, 10 Hp, 14 A, 460 V, R3

MPN3AUD0000000714
Active

ABB ACH580 HVAC enclosed ultra-low harmonic drive with circuit breaker, 3-phase, 440-480 V, 10 Hp light-overload UL, 14 A, IP21, NEMA Type 1, frame R3.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AUD0000000714 — Input / Supply
ParameterValue
Input voltage range440 ... 480 V
Number of phases3-phase
Frequency50/60 Hz
3AUD0000000714 — Power & Output
ParameterValue
Output current, light overload (UL rating)14 A
Output power, light overload (UL rating, Hp)10 Hp
3AUD0000000714 — Mechanical & Cooling
ParameterValue
Frame sizeR3
NEMA enclosure typeType1
Degree of protection (IP)IP21

Product details

HVAC drive with integrated harmonic mitigation

The ABB 3AUD0000000714 is an enclosed ultra-low harmonic drive with a built-in circuit breaker and a UL light-overload rating of 10 Hp at 14 A on a 460 V supply. Rated for 440-480 V three-phase input at 50/60 Hz, it ships in a NEMA Type 1 enclosure with IP21 protection — suitable for indoor mechanical rooms and rooftop units where drips and falling dirt are the main contaminants, not washdown. The R3 frame size is the physical footprint; expect a compact panel-mount unit that fits standard HVAC cabinet layouts without excessive clearances.

The 10 Hp light-overload (14 A) UL rating is the continuous motor capacity at 460 V for variable-torque HVAC loads like fans and centrifugal pumps. Light-overload means the drive can deliver 110 % current for 60 s — enough for fan inertia starts, not for high-breakaway conveyor loads. The built-in circuit breaker eliminates the need for a separate branch-circuit protective device, saving a panel space slot. The ultra-low harmonic design (<5 % THDi typically) meets IEEE 519 without external filters, which simplifies compliance for VFD retrofits in existing buildings. IP21 and NEMA Type 1 mean the enclosure is drip-proof and finger-safe but not sealed against hose-down or dust — keep it in conditioned indoor spaces.

Frequently asked questions

What is the frame size of 3AUD0000000714?

The frame size is R3, which determines the physical mounting footprint and conduit entry locations for this ACH580 drive.

What input voltage and frequency does this drive accept?

It accepts 440-480 V three-phase at 50/60 Hz, covering standard North American and 50 Hz global industrial supplies within that band.

What enclosure type and protection rating does this drive have?

NEMA Type 1 enclosure with IP21 protection — suitable for indoor installation where the drive is protected from dripping water and accidental contact, but not from hose-down or outdoor weather.

MPN
3AUD0000000714