Skip to main content
ABB 3AUD0000003532 — AC Drive (VFD) 480V

ABB 3AUD0000003532 ACQ580 Irrigation Drive, 60 Hp, 77 A, 460

MPN3AUD0000003532
Active

ABB ACQ580-3P-077A-4+C192+F289, LV AC 3R irrigation drive package, UL: Pld 60 Hp, 77 A, 460 V, 3-phase, 50/60 Hz, NEMA Type 1, IP21, Frame Size R6.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AUD0000003532 — Input / Supply
ParameterValue
Input voltage range440 ... 480 V
Number of phases3-phase
Frequency50/60 Hz
3AUD0000003532 — Power & Output
ParameterValue
Output current, light overload (UL rating)77 A
Output power, light overload (UL rating, Hp)60 Hp
3AUD0000003532 — Mechanical & Cooling
ParameterValue
Frame sizeR6
NEMA enclosure typeType1
Degree of protection (IP)IP21
3AUD0000003532 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)50 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)65 A

Product details

Drive package for irrigation duty

The ABB 3AUD0000003532 is an ACQ580 series LV AC drive package configured for 3R irrigation applications. It carries UL ratings for both light-overload (60 Hp, 77 A) and heavy-duty (50 Hp, 65 A) use at 460 V, 3-phase, 50/60 Hz. The NEMA Type 1 enclosure with IP21 protection suits indoor or sheltered outdoor pump houses — not direct washdown, but fine for a dry irrigation panel.

The 77 A light-overload rating at 460 V governs the nominal pump motor sizing — that's the continuous current the drive can deliver without derating. The 65 A heavy-duty rating applies when the load profile demands higher peak torque or a wider constant-torque speed range; a 50 Hp irrigation pump running at variable flow would typically land here. Frame size R6 indicates the physical footprint and bus-bar layout — confirm the gland-plate clearance and mounting hole pattern against the existing panel cutout before ordering.

Frequently asked questions

What is the frame size of 3AUD0000003532?

Frame size R6. This determines the physical dimensions, bus-bar layout, and mounting pattern — verify panel cutout clearance before specifying.

What input voltage and frequency does this drive accept?

Input voltage range is 440 to 480 V, 3-phase, at 50/60 Hz — standard North American 460 V class.

What are the UL output ratings for heavy-duty and light-overload use?

Heavy-duty (HD) use: 50 Hp, 65 A. Light-overload (LO) use: 60 Hp, 77 A. Both at 460 V. The LO rating governs continuous pump duty; the HD rating applies when the load demands higher peak torque or a wider constant-torque range.

Where can I buy 3AUD0000003532 and how is it quoted?

Sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, not a stock promise.