ABB 3AUD0000004270 — AC Drive (VFD) 600V

ABB 3AUD0000004270 HVAC Packaged Drive, 60 Hp, 62 A, 500-600

MPN3AUD0000004270
Active

ABB 3AUD0000004270 HVAC packaged drive with e-clipse bypass and circuit breaker disconnect, UL: Pld 60 Hp, 62 A, 500...600 V, 3-phase, 50/60 Hz, NEMA Type3R.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AUD0000004270 — Electrical (input)
ParameterValue
Input voltage range500 ... 600 V
Number of phases3-phase
Frequency range50/60 Hz
3AUD0000004270 — Output / Performance
ParameterValue
Output power (UL), light overload60 Hp
Output current (UL), light overload62 A
3AUD0000004270 — Mechanical
ParameterValue
NEMA enclosure typeType3R

Product details

HVAC packaged drive with e-clipse bypass

The ABB 3AUD0000004270 is an HVAC packaged drive combining a variable-frequency drive with an e-clipse bypass and a circuit breaker disconnect in a single NEMA Type3R enclosure. It's built for 3-phase 500... 600 V input at 50/60 Hz, and carries a UL light-overload rating of 60 Hp / 62 A — the number that governs motor sizing for UL-listed installations.

The 62 A light-overload current (UL) is the continuous output the drive can deliver to a 60 Hp motor without tripping on overload — that's your sizing anchor. The 500... 600 V input range covers 480 V and 575 V nominal supplies common in North American industrial and commercial HVAC, but the drive's own minimum is 500 V, so a 480 V line is below the rated floor; verify your actual supply voltage against the 500 V minimum before specifying. NEMA Type3R means the enclosure is rainproof and sleet-resistant — suited for outdoor rooftop or wall-mounted HVAC installations where the drive sees weather but not hose-down. It's not a washdown rating; if the location gets hosed, you need Type4 or 4X.

The NEMA Type3R packaged format includes the bypass and disconnect inside the same enclosure — no separate contactor, overload relay, or disconnect switch to panel-build around. That saves enclosure space and wiring labor on rooftop units or mechanical-room walls. The circuit breaker disconnect serves as both service-disconnect and branch-circuit protection, so the feeder only needs upstream short-circuit protection.

Frequently asked questions

What is the input voltage range for 3AUD0000004270?

The input voltage rating is 500... 600 V, 3-phase, 50/60 Hz. Note the 500 V minimum — a 480 V supply is below the rated floor.

What is the UL output rating for this drive?

UL light-overload rating is 60 Hp and 62 A — that's the continuous output for motor sizing in UL-listed installations.

Where can I buy 3AUD0000004270?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.