ABB 3AUD0000004274 — AC Drive (VFD) 600V

ABB 3AUD0000004274 HVAC Packaged Drive, 150 Hp UL, 144 A, 50

MPN3AUD0000004274
Active

ABB, ACH580 series, HVAC packaged drive with e-clipse bypass and circuit breaker disconnect, UL: Pld 150 Hp, 144 A, 3-phase, 500-600 V, NEMA 3R, 50/60 Hz.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AUD0000004274 — Electrical (input)
ParameterValue
Input voltage range500 ... 600 V
Number of phases3-phase
Frequency range50/60 Hz
3AUD0000004274 — Output / Performance
ParameterValue
Output power (UL), light overload150 Hp
Output current (UL), light overload144 A
3AUD0000004274 — Mechanical
ParameterValue
NEMA enclosure typeType3R

Product details

The ABB 3AUD0000004274 is an HVAC packaged drive from the ACH580 series, integrating an e-clipse bypass and a circuit breaker disconnect in a single NEMA 3R enclosure. It's UL-rated for light-overload use at 150 Hp and 144 A, fed by a 3-phase, 500-600 V input at 50/60 Hz. That NEMA 3R rating means it's built for outdoor or unconditioned indoor mounting — rain-tight and sleet-resistant, but not submersible. For a panel builder, the bypass means the fan or pump keeps running even if the drive faults out; the circuit breaker disconnect gives you a local lockable means of isolation without adding a separate disconnect switch.

The 144 A light-overload current (UL) is the number that governs conductor sizing and upstream protection for the drive input. Light-overload means it's sized for variable-torque HVAC loads — fans, centrifugal pumps — where the motor rarely pulls more than nameplate current. The 500-600 V input range covers 480 V and 575 V nominal systems common in North American industrial plants; the 50/60 Hz frequency rating means it's not picky about line frequency, so the same unit works on 50 Hz or 60 Hz grids. The 3-phase input is standard for drives this size; single-phase isn't supported.

Frequently asked questions

What is 3AUD0000004274's input voltage and frequency?

The drive accepts a 3-phase input voltage of 500 to 600 V at 50/60 Hz, covering 480 V and 575 V nominal systems.

What is the UL output rating for 3AUD0000004274?

Under UL light-overload use, the drive is rated for 150 Hp output power and 144 A output current, sized for variable-torque HVAC loads like fans and centrifugal pumps.

What enclosure type is 3AUD0000004274?

The drive is housed in a NEMA 3R enclosure, making it suitable for outdoor or unconditioned indoor mounting where rain, sleet, and ice resistance is needed.

Where can I buy 3AUD0000004274 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
3AUD0000004274