The 3AXD50000031884: Three duty ratings are listed: normal use at 2.2 kW / 9.8 A, heavy-duty at 1.5 kW / 7.8 A, and light-overload at 2.2 kW / 9.3 A. The heavy-duty figure governs continuous motor load on a constant-torque application like a conveyor or mixer; the light-overload curve suits variable-torque fans and pumps where peak current only appears during acceleration. UL versions mirror these: heavy-duty UL at 2 Hp / 7.5 A, light-overload UL at 2 Hp / 9.3 A.
Integration notes
Mounts as a module; The R2 frame is compact — fits a standard backplate without crowding adjacent breakers or contactors. Analog inputs: 2; analog output: 1. The MODBUS port is the only hardware interface — no built-in Ethernet. Sound level is 58.8 dB(A), so it's audible in a quiet control room but not intrusive in a machine hall. Operating humidity range is 5 to 95% RH. The drive includes no battery or cell.