Skip to main content
ABB 3AXD50000031890 — AC Drive (VFD) 480V

ABB 3AXD50000031890 R1 Drive Module, 2.2 kW / 5.6 A, 380–480

MPN3AXD50000031890
Active

ABB R1 frame drive module, 3-phase 380–480 V input, 2.2 kW / 5.6 A normal-use output, MODBUS, IP20, includes control unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000031890 — Power & Output
ParameterValue
Output power, normal duty2.2 kW
Output current, normal duty5.6 A
Output power, heavy duty1.5 kW
Output current, heavy duty4.0 A
Output power, light overload2.2 kW
Output current, light overload5.3 A
Output current, light overload (UL rating)4.8 A
Apparent power output3.9 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)3 Hp
Standby power loss15 W
3AXD50000031890 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000031890 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000031890 — Environmental
ParameterValue
Temperature rating (max.)Maximum 50 °C
3AXD50000031890 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)2 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)3.5 A

Product details

What this R1 drive module delivers

The ABB 3AXD50000031890 is an R1-frame drive module rated for 2.2 kW normal-use output at 5.6 A (In), with a heavy-duty rating of 1.5 kW / 4.0 A (IhD). Input is 380–480 V three-phase, 47.5–63 Hz. MODBUS RTU is onboard via a hardware interface; no add-on card required for basic serial comms.

Load profiles and derating

Three duty ratings are listed: light-overload (PlD 2.2 kW / 5.3 A), normal-use (Pn 2.2 kW / 5.6 A), and heavy-duty (PhD 1.5 kW / 4.0 A). UL-listed heavy-duty output is 2 Hp / 3.5 A, and UL light-overload is 3 Hp — useful when the panel requires a UL-marked drive.

Frame size R1, IP20 open-type enclosure, module mounting. Ambient temperature limit is 50 °C; derate above that. Operating humidity range 5–95 % RH. Standby loss is 15 W, power consumption under load 91 W. Sound level 63.1 dB(A). Altitude rating 1000 m without derating. Includes the control unit — no separate ordering step for the logic section. Two analog inputs, one analog output; five digital inputs and two digital outputs are available for basic I/O without an expansion module.

Frequently asked questions

What compliance documentation is available for this drive?

RoHS compliance follows EU Directive 2011/65/EU and Amendment 2015/863 (date 20230303). REACH declaration confirms substances above 0.1 mass percentage (date 20250905). The SCIP number is df417ff4-f8a5-4aa8-b5b9-bb43623953af Finland. UL ratings are listed for heavy-duty (2 Hp / 3.5 A) and light-overload (3 Hp).

What are the key output ratings for normal and heavy duty?

Normal-use output is 2.2 kW at 5.6 A; heavy-duty output is 1.5 kW at 4.0 A. Light-overload output is 2.2 kW at 5.3 A. UL normal-use current is 4.8 A.

MPN
3AXD50000031890