Skip to main content
ABB 3AXD50000031892 — AC Drive (VFD) 480V

3AXD50000031892 AC Drive, 4 kW, 9.4 A, Frame R1

MPN3AXD50000031892
Active

ABB ACS580 drive, frame size R1, 380-480 V 3-phase input, 4 kW / 9.4 A normal-use output, IP20, MODBUS.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000031892 — Power & Output
ParameterValue
Output power, normal duty4 kW
Output current, normal duty9.4 A
Output power, heavy duty3.0 kW
Output current, heavy duty7.2 A
Output power, light overload4.0 kW
Output current, light overload8.9 A
Output current, light overload (UL rating)7.6 A
Apparent power output6.5 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)5 Hp
Standby power loss15 W
3AXD50000031892 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000031892 — Mechanical & Cooling
ParameterValue
Frame sizeR1
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000031892 — Environmental
ParameterValue
Temperature rating (max.)Maximum 50 °C
3AXD50000031892 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)3 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)6.0 A

Product details

The ABB 3AXD50000031892 is a general-purpose AC drive in frame size R1, delivering 4 kW normal-use output at 9.4 A from a 380-480 V three-phase supply. It carries a current-production lifecycle status, so this is a standard BOM line — not an end-of-life or NRND part.

MODBUS RTU is onboard as standard. The drive includes 2 analog inputs, 1 analog output, 5 digital inputs, and 2 digital outputs.

Physical installation and environment

Frame R1 mounts as a module, IP20, so it goes inside a panel.

Frequently asked questions

What are the key output ratings for this drive?

Normal-use output is 4 kW at 9.4 A; heavy-duty use is 3.0 kW at 7.2 A; light-overload use is 4.0 kW at 8.9 A. UL derated values are 7.6 A normal-use and 6.0 A heavy-duty.

What communication protocol does this drive support?

MODBUS RTU is standard. No industrial Ethernet interface is built in.

What is the SCIP number and why is it important?

The SCIP number is df417ff4-f8a5-4aa8-b5b9-bb43623953af Finland. It is required for EU waste reporting under the Waste Framework Directive for articles containing Substances of Very High Concern.

What compliance certifications does this drive carry?

RoHS compliant (2011/65/EU + 2015/863), REACH declared (substances >0.1% present), and UL listed for both normal-use and heavy-duty current ratings.

MPN
3AXD50000031892