Skip to main content
ABB 3AXD50000031893 — AC Drive (VFD) 480V

ABB 3AXD50000031893 Drive Module, 5.5 kW, 12.6 A

MPN3AXD50000031893
Active

ABB drive module, frame size R2, 5.5 kW normal-use output, 12.6 A, 380–480 V 3-phase, IP20, Modbus, IE2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3AXD50000031893 — Power & Output
ParameterValue
Output power, normal duty5.5 kW
Output current, normal duty12.6 A
Output power, heavy duty4.0 kW
Output current, heavy duty9.4 A
Output power, light overload5.5 kW
Output current, light overload12.0 A
Output current, light overload (UL rating)11 A
Apparent power output8.7 kV·A
Efficiency class (IE)IE2
Output power, light overload (UL rating, Hp)7.5 Hp
Standby power loss16 W
3AXD50000031893 — Input / Supply
ParameterValue
Input voltage range380 ... 480 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
3AXD50000031893 — Mechanical & Cooling
ParameterValue
Frame sizeR2
NEMA enclosure typeOpen Type
Degree of protection (IP)IP20
Mounting typeModule
3AXD50000031893 — Environmental
ParameterValue
Temperature rating (max.)Maximum 50 °C
3AXD50000031893 — Electrical
ParameterValue
Technical UL/Output Power, Heavy-Duty Use (UL)5 Hp
Technical UL/Output Current, Heavy-Duty Use (UL)7.6 A

Product details

The ABB 3AXD50000031893 is a drive module in frame size R2, delivering 5.5 kW normal-use output at 12.6 A from a 380–480 V three-phase supply. Heavy-duty use drops to 4.0 kW and 9.4 A — enough for a 4-pole induction motor on a conveyor or pump. Modbus is onboard, so it ties into a PLC without an extra option card. IE2 efficiency keeps standby loss at 16 W.

The normal-use current (12.6 A) is the continuous rating at 50 °C ambient — size your motor cable and overload protection to that. Heavy-duty (9.4 A) applies when the load profile includes frequent starts or short overloads; the drive handles 4.0 kW in that duty class. UL-listed normal-use current is 11.0 A, and heavy-duty power is 5 Hp, so the same drive works on a North American 5 Hp motor with the appropriate branch-circuit protection. IP20 means it is for indoor panel mounting only — no washdown or dust-tight enclosure. Frame size R2 determines the DIN-rail footprint and gland-plate cutout; verify panel depth for the module depth plus cabling bend radius.

Integration notes

Mount the module on a flat panel or DIN rail inside an IP20 enclosure. The 2 analog inputs and 1 analog output handle speed reference and actual-value feedback; 5 digital inputs and 2 digital outputs cover start/stop, fault reset, and status. Modbus RTU at 47.5–63 Hz line frequency — set the node address via the drive parameter group. No battery inside, so no periodic replacement.

Frequently asked questions

What compliance documentation does ABB provide for this drive?

RoHS compliance following EU Directive 2011/65/EU (date 20230303), REACH declaration (date 20250905), and SCIP number cd4e0d31-f9a3-400d-a002-4c686402b059 Finland for EU waste reporting. UL listing is also on file.

What is the maximum ambient temperature for this drive?

Rated for a maximum ambient of 50 °C.

What communication protocol does it support?

Modbus is the onboard protocol.

MPN
3AXD50000031893