Skip to main content
ABB 3AXD50000036388 — AC Drive (VFD) 240V

ABB 3AXD50000036388 ACS880 drive module, 1.5 kW, 8 A, 230 V

MPN3AXD50000036388
Active

ABB ACS880 LV AC machinery drive module, frame R1, 1.5 kW / 8 A normal use, 200-240 V 3-phase, IP20, CAN interface.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3AXD50000036388 — Electrical Output
ParameterValue
Output power, normal duty (Pn)1.5 kW
Output current, normal duty (In)8 A
Output power, heavy duty (PhD)1.1 kW
Output current, heavy duty (IhD)6 A
Output power, light-overload duty (PlD)1.5 kW
Output current, light-overload duty (IlD)7.6 A
Output power, heavy duty (UL, Hp)1.5 Hp
Output current, heavy duty (UL)6 A
Apparent power output3.2 kV·A
Output power, light-overload duty (UL, Hp)2 Hp
Efficiency class (IE)IE2
Output current, light-overload duty (UL)7.6 A
Standby loss29 W
3AXD50000036388 — Electrical Input
ParameterValue
Input voltage range200 ... 240 V
Number of phases3-phase
Frequency47.5 ... 63 Hz
Power factor0.98
3AXD50000036388 — Control & I/O
ParameterValue
Digital inputs / outputs6 / 5
Communication protocolCAN
Analog inputs2
Analog outputs2
Hardware interfacesIndustrial Ethernet 0
3AXD50000036388 — Environmental
ParameterValue
Temperature rating, max.Maximum 40 °C
Operating humidity5 ... 95
Altitude1000 m
Noise level47 dB(A)
3AXD50000036388 — Mechanical
ParameterValue
Degree of protection (IP)IP20
Enclosure type (NEMA)Open Type
Frame sizeR1
Mounting typeModule
3AXD50000036388 — Approvals
ParameterValue
RoHS complianceFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
REACH complianceTrue - contains substances > 0.1 mass percentage

Product details

The 3AXD50000036388: Frame R1 mounts as a module; IP20 enclosure, open type per NEMA. Maximum ambient temperature 40 °C, altitude 1000 m, humidity 5-95% non-condensing. Sound level 47 dB(A). Standby loss 29 W. Power factor 0.98.

Equipped with 2 analog inputs, 2 analog outputs, and 6 digital inputs / 5 digital outputs. Communication via CAN protocol; no onboard Industrial Ethernet interface. Includes a PC connection port. Internal lithium coin cell (CR2032, 220 mAh, 3 V, 2 pcs) for real-time clock backup.

Frequently asked questions

What are the key power ratings for this drive module?

Normal-use output is 1.5 kW at 8 A; heavy-duty use is 1.1 kW at 6 A; light-overload use is 1.5 kW at 7.6 A. UL ratings are 2 Hp light-overload and 1.5 Hp heavy-duty.

What compliance documentation is available for 3AXD50000036388?

RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 (date 20240508). REACH declaration (date 20250905) notes substances above 0.1 mass percentage. SCIP number 8a7e10d7-3960-4da3-8cd8-3a7488ee171b Finland. UL listing covers heavy-duty and light-overload horsepower ratings.

What is the input voltage and frequency range?

Input voltage is 200-240 V three-phase, frequency 47.5-63 Hz.

MPN