Duty ratings and overload capability
The 3AXD50000036393: Normal-use output is 7.5 kW / 30 A; heavy-duty use drops to 5.5 kW / 24 A, and light-overload use holds at 7.5 kW / 28 A. Under UL listing, heavy-duty power is 7.5 Hp / 24 A, light-overload 10 Hp / 28 A. The 0.98 power factor and IE2 efficiency level keep line draw clean.
Environmental limits and compliance
Rated for maximum 40 °C ambient, 1000 m altitude, and 5–95 % RH. IP20 open-type enclosure suits cabinet mounting. The module carries a current lifecycle stage; RoHS compliance dated 20240508 and REACH compliance dated 20250905 are on record. SCIP number fcbdffac-2627-4666-9149-f2307acecd9a Finland is listed for waste tracking under WEEE Category 4 (Large Equipment).
Provides 2 analog inputs, 2 analog outputs, 6 digital inputs, and 5 digital outputs. Communication is via CAN; no onboard Industrial Ethernet. The module includes a CR2032 lithium coin cell (220 mAh, 3 V, 2 pcs) for backup.