The 3AXD50000036396: Under UL listing, light-overload use is rated 15 Hp, 46 A; heavy-duty use at 44 A. The apparent power output is 20 kV·A, and the drive achieves IE2 efficiency level.
The 50 A normal-use output (In) is the figure to match against your motor FLA for continuous duty. Heavy-duty use drops to 44 A (IhD) — that's the number for high-start-torque or cyclic loads. Light-overload use sits at 46 A (IlD). All three power ratings land at 11 kW, so the drive is current-limited, not power-limited, in this voltage band. Input voltage range is 200–240 V three-phase, frequency 47.5–63 Hz. Ambient temperature max 40 °C, altitude 1000 m without derating. Enclosure is IP20 Open Type — plan for a clean, dry cabinet. The module includes a PC connection, 2 analog inputs and 2 analog outputs, plus 6 digital inputs and 5 digital outputs. Communication is CAN-based; there is no onboard Industrial Ethernet interface.
Standby loss is 31 W; sound pressure level 71 dB(A). The module uses a lithium coin cell (CR2032, 220 mAh, 3 V, two pieces) for backup.
Sourcing
No cross-reference or second-source is available — specify the 3AXD50000036396 directly into the BOM.