Duty ratings that matter
The 3AXD50000046388: Normal-use output is 18.5 kW / 23 A; heavy-duty use drops to 15 kW / 19 A. Light-overload use sits at 18.5 kW / 22 A. UL ratings align: heavy-duty 15 Hp / 19 A, light-overload 20 Hp / 22 A. No normal-use UL current is listed, but the heavy-duty number is the binding one for North American code compliance.
Environment and mounting
Standby loss is 25 W — negligible for panel thermal budgeting. Sound level 60 dB(A), typical for a drive this size; no special enclosure needed for noise.
WEEE category 5 (small equipment). Battery pack: two CR2032 lithium coin cells, 220 mAh each, 3 V — accounted for in end-of-life processing.
Two analog inputs, two analog outputs, six digital inputs, two digital outputs. Communication is CAN-based — no onboard Industrial Ethernet. If you need PROFINET or EtherNet/IP, plan for an optional fieldbus adapter module.